| Parameter | Specification |
| Size (Outer Diameter) | OD ≥ 0.25 mm, customizable upon request |
| Wall Thickness | Customizable upon request |
| Af Temperature | 0 ± 10°C |
| Tensile Strength | 850 ~ 1900 MPa |
| Elongation | 10% ~ 20% |
| Surface Condition | Oxidized, Ground |
| Product Description | Plays a key role in the development and manufacturing of high-end medical devices, such as cardiovascular stents and minimally invasive interventional devices (e.g., filters, catheters). |
| Standard | ASTM F2063-18 |